Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 87 dokumen yang sesuai dengan query
cover
Windy Warna Irawan
"Skripsi ini membahas mengenai kelompok minoritas seksual LGBTIQ schagai subjek hak dan hubungannya dengan negara schagai institusi penjamin hak asasi manusia. Penelitian ini menggunakan metodc analisis deskriptif dan studi kepustakaan. Hasil dari pcnclilian ini menyatakan bahwa ada keperluan untuk menguhah konsep 11AM schagai sesuatu yang terkonstruksi secant social agar kelompok minoritas seksual LG13'I IQ dapat diakui sebagai subjek hak dan mendapatkan penghormatan, pemenuhan, serta perlindungan atas hak dan kepentingan mereka dari negara. Sislem negara demokrasi menjadi wadah politik yang sesuai untuk memherikan emansipasi kepada kelompok minoritas seksual LGBTIQ.

This thesis discussed about sexual minority group LGBTIQ as the subject of rights and its relation with the state as the human rights guarantor institution. This research used analitical descriptive and bibliography study methods. The result of this research declares that there is a need to change the conception of human rights into something that construct socially so that the sexual minority group LGBTIQ can he recognized as the subject of rights and get hold of respect, fulfillment, along with protection for their rights and interests that come from the state. The democracy state system became an appropriate political institution to give the sexual minority group I.GBTIQ emancipations."
Depok: Fakultas Ilmu Pengetahuan dan Budaya Universitas Indonesia, 2010
S16072
UI - Skripsi Open  Universitas Indonesia Library
cover
Steffi Magdalena Jayanti
"Penulisan skripsi ini berawal dari ketidakjelasan konsep subyek, fantasi, dan emansipasi dalam keadaan kapitalisme-globalisasi. Subyek yang bersifat void ini selalu berupaya menutupi lackness alamiahnya. Salah satu upaya yang dilakukan adalah melalui fantasi. Prinsip dasar fantasi adalah 'Che vuoi' (What do you want from me?). Hasrat pihak lainlah yang secara tidak sadar membentuk hasrat seseorang, contohnya pada kasus fantasi rasis. Problematika ini memampukan subyek untuk melampaui sisi tergelapnya, sehingga terkait dengan emansipasi. Kondisi emansipasi merupakan tujuan perjuangan subyek. Perjuangan tersebut membutuhkan subyek yang mempunyai kemampuan mengatasi lackness alamiahnya melalui tindakan radikal. Tindakan radikal ini dapat terjadi dengan adanya pematahan struktur the Big Other, serta pelepasan diri dari tatanan the Symbolic yang ada. Tindakan radikal ini menghasilkan kebaruan dan subyek 'kosong'. Situasi inilah yang memungkinkan tercapainya emansipasi. Perlu diingat bahwa emansipasi tidak bisa berhenti, tidak mempunyai syarat-syarat legal, serta bukanlah sebuah fantasi (karena bukan bentukan hasrat pihak lain).

This thesis begins with the vagueness concept of subject, fantasy, and emancipation in capitalist-globalization. Subject, whose characteristic is void, always try to cover this natural lackness. One of the efforts is through fantasy. The basic principle of fantasy is 'Che vuoi' (What do you want from me?). Other party desire unconsciously forms one's desires, for example in the case of racist fantasy. This problematic enabling the subject to pass over the darkest side of his/her life, which associated with emancipation. Emancipation is a condition that being the goal of subject's struggle. This struggle requires a subject that has the ability to overcome his/her natural lackness through radical action. This radical action may occur by the breaking the structure of the Big Other, as well as the self-release from the existing the Symbolic order. This radical action produces novelty (new form) and the an "empty" subject. This situation allows the possibility of emancipation. Some things that we should keep in our mind that emancipation won't have finished, it doesn't have any legal terms, and it's not a fantasy (as it's not formed by the other party's desire)."
Depok: Fakultas Ilmu Pengetahuan dan Budaya Universitas Indonesia, 2012
S42232
UI - Skripsi Open  Universitas Indonesia Library
cover
Hendri Dwi Saptioratri Budiono
"Ventilator adalah alat kesehatan yang bermanfaat untuk memberikan aliran udara (ventilasi) dan mengendalikan pola pernapasan pasien berbasis sistem pneumatic. Alat ini lahir pada saat adanya wabah covid 19 di tahun 2020, sehingga diberi nama COVENT-20 (Covid Ventilator 2020). Alat ini dirancang untuk mudah dibawa dan dan sesuai untuk keadaan darurat. Kelebihan lain dari COVENT-20 adalah adanya 2 (dua) mode operasi yaitu mode CPAP (continuous positive airway pressure) yang memungkinkan bekerja saat kondisi pasien masih sadar untuk membantu oksigenasi ke paru-paru pasien dan mode CMV (continuous mandatory ventilation) yang bekerja ketika pasien tidak sadar atau mengalami kesulitan mengatur pernafasannya untuk mengambil alih fungsi pernafasan pasien. Kedua mode tersebut dapat digunakan pada saat pasien berada di rumah maupun dalam perjalanan (di mobil ambulance), namun tidak digunakan di ruang isolasi. Tim Riset dan Pengembang Ventilator UI yang saya pimpin adalah merupakan kolaborasi dari para peneliti di Fakultas Teknik UI (FTUI) dan Fakultas Kedokteran UI (FKUI), Rumah Sakit Cipto Mangunkusumo (RSCM), RSUP Persahabatan Jakarta, Politeknik Kesehatan Kementerian Kesehatan Jakarta II Jurusan Teknik Elektromedik, Ikatan Alumni Fakultas Teknik UI (ILUNI FTUI). Fase uji produk COVENT-20 dilakukan pada pada Balai Pengamanan Fasilitas Kesehatan (BPFK) Jakarta, Direktorat Jenderal Pelayanan Kesehatan, Kementerian Kesehatan RI dan dinyatakan lolos uji produk per tanggal 4 Mei 2020 dengan nomor Laporan Uji Produk YK.01.03/XLVIII.2/1312/2020. Uji Klinik COVENT-20 dilakukan dan dinyatakan lolos Uji dengan mendapatkan Ijin Edar dari Kementerian Kesehatan Republik Indonesia, Direktorat Jenderal Kefarmasian Dan Alat Kesehatan, pada 19 Juni 2020 dengan No Ijin Edar KEMENKES RI AKD 20403021003. Pada fase donasi, 300 COVENT-20 dikerjakan oleh beberapa mitra Produsen Alat Kesehatan (Alkes) diantaranya PT Enesers Mitra Berkah, PT Graha Teknomedika, dan PT PINDAD dan dikalibrasi oleh beberapa mitra Perusahaan Kalibrasi Alkes. Penggalangan dana dilakukan dibawah koordinasi Ikatan Alumni FTUI (ILUNI FTUI) termasuk distribusi dan supervisi ke banyak rumah sakit pilihan di Indonesia dari Aceh hingga Papua. Perjalanan Panjang menuju fase komersialisasi diawali dengan penyesuaian regulasi dan aturan di UI. Dibantu oleh Direktorat Inovasi dan Inkubator Bisnis Universitas Indonesia (DISTP UI), saat ini Covent-20 sudah dikomersialisasi oleh CV. Bartec Utama Mandiri dan sudah berhasil masuk pada list e-catalog alat Kesehatan RI, sehingga dapat dimanfaatkan dengan mudah oleh masyarakat luas.

Research and Production Management of Ventilator Transport Covent 20 Project: From Idea to Commercialization
A ventilator is a medical device that gives air flow (ventilation) and controls a patient’s breathing pattern based on a pneumatic system. The device was invented during the covid-19 pandemic in 2020 named COVENT-20 (Covid Ventilator 2020). This device is designed to be easy to transport and suitable for emergencies. The advantages of COVENT-20 is that it has two operation mode: (1) CPAP (continuous positive airway pressure), which works during the patient’s conscious state, supporting the lungs’ oxygenation, and (2) CMV (continuous mandatory ventilation) which works during the patient’s unconscious or difficult to breathe state and control the breathing function system. Both modes can be used at home or during mobility (in an ambulance) but not in the isolation room. The research team and developer of Ventilator UI, which I lead, are a collaboration of the researcher at the Faculty of Engineering Universitas Indonesia (FTUI) and Faculty of Medicine Universitas Indonesia (FKUI), Cipto Mangunkusuomo National Central General Hospital (RSCM), Persahabatan Central General Hospital (RSUP), Electromedical Engineering Study Program of Politeknik Kesehatan Kementerian Kesehatan Jakarta II, and Alumni association of FTUI (ILUNI FTUI). The product testing phase of COVENT-20 is done in the Hall of Health Facility Security (BPFK) Jakarta, Directorate General of Health Service, Ministry of Health Republic of Indonesia, and is stated to pass the product testing on 4th Mei 2020 with the Product Testing Report number YK.01.03/XLVIII.2/1312/2020. The clinical testing for COVENT-20 is done and stated to pass the test from the Directorate General of Pharmacy and Medical Devices, Ministry of Health Republic of Indonesia on 19th June 2020 with Distribution Permit number KEMENKES RI AKD 20403021003. In the donation phase, 300 COVENT-20s are produced by several collaborators for medical device producers consisting of PT Enesers Mitra Berkah, PT Graha Teknomedika, and PT PINDAD and calibrated by several collaborators of Medical Device Calibration Companies. The crowdfunding is done under the coordination of ILUNI FTUI, followed by distribution and supervision to many designated hospitals in Indonesia from Aceh to Papua. The long road to the commercialization phase started with UI regulations and rules adjustment. Supported by the Directorate of Innovation and Business Incubator Universitas Indonesia (DISTP UI), now the COVENT-20 has been commercialized by CV. Bartec Utama Mandiri and successfully included in the Medical Devices E-Catalog Republic of Indonesia so that the device can be used widely by society.
"
Depok: Fakultas Teknik Universitas Indonesia, 2022
PR-pdf
UI - Tugas Akhir  Universitas Indonesia Library
cover
Steve Immanuel Yahya
"Berdasarkan data eKatalog LKPP tahun 2019-2021, transaksi alat kesehatan di Indonesia masih didominasi produk impor, yakni sebanyak 88%. Patient monitor merupakan salah satu alat medis yang berperan penting untuk membantu dokter mendiagnosa kondisi pasien. Pandemi Covid-19 menciptakan momentum untuk penelitian berbasis health monitoring, terlihat dari banyaknya penelitian di tahun 2020-2023 tentang patient monitor menggunakan STM32, Arduino, dan STM32. Oleh karena itu, penelitian ini mengembangkan modul pemantauan saturasi oksigen dan denyut jantung berbasis mikrokontroler STM32F411CEU6 untuk aplikasi patient monitor. Modul yang dikembangkan menggunakan sensor MAX30102 dengan akurasi pemantauan saturasi oksigen sebesar 98.942%, dan akurasi pemantauan denyut jantung sebesar 80.6855%.

Based on data from the LKPP eCatalog for the years 2019-2021, the transaction of medical devices in Indonesia is still dominated by imported products, accounting for 88%. On the other hand, patient monitors are essential medical devices that assist doctors in diagnosing patient conditions. Furthermore, the Covid-19 pandemic has created momentum for health monitoring research, evident from numerous studies conducted between 2020 and 2023 on patient monitors powered by STM32, Arduino, and STM32 platforms. Therefore, this research develops an oxygen saturation and heart rate monitoring module based on the STM32F411CEU6 microcontroller for patient monitor applications. The developed module utilizes the MAX30102 sensor with an oxygen saturation monitoring accuracy of 98.942% and a heart rate monitoring accuracy of 80.6855%."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rofan Aziz
"ABSTRAK
Penggunaan peralatan telemedis memiliki kelebihan karena kebutuhan daya yang kecil dan dapat digunakan secara portabel. Salah satu alternatif pemilihan bahan antena untuk sistem wearable applications adalah dengan menggunakan antena tekstil. Pada tesis ini dilakukan rancang bangun antena tekstiltipe magnetik pada frekuensi 2,45GHz dengan menggunakan desain yang terinspirasi dari motif batik mega mendung (batik Cirebon), serta penggunaan model tubuh manusia berupa phantom untuk mengetahui pengaruh tubuh manusia terhadap kinerja antena yang diletakkan di dekatnya. Dalam tesis ini, dirancang dua tipe antena yang bersifat magnetik yaitu microstrip spiral antenna (tipe-1) dan microstrip spiral slot antenna (tipe-2) menggunakan metode finite integration technique (FIT).Berdasarkan analisis dari hasil simulasi, antena tipe-1 dantipe-2 memilikikecenderungan sebagai antena magnetik, dimana hal ini dapat dilihat dari besaranintensitas medan listrik (E) dan medan magnet (H) pada area di sekitar medan dekat (near field) antena. Hasil simulasi dan pengukuran menunjukkan hasil unjuk kerja antena tipe-1 memiliki frekuensi resonansi di 2,45 GHz,dengan nilai|S11|berturut-turut24,15 dB dan12,09 dBdi udara bebas.Bandwidth impedansi (VSWR  2)sebesar 27,10 MHz (1,1%) dan 40 MHz (1,6%) berturut-turut untuk simulasi dan pengukuran.Gain antena didapatkan 0,96 dBi (simulasi) dan 0,42 dBi (pengukuran).Ketika antena tipe-1 ini diletakkan di dekat model tubuh manusia (phantom) didapatkan nilai specific absorption rate (SAR) sebesar 0,00083 W/Kg pada standar 10g rata-rata jaringan tubuhdengan daya masukan 1 mW. Pada antena tipe-2, hasil simulasi dan pengukuran menunjukkan unjuk kerja |S11| berturut-tutut sebesar -21,61 dB dan -24,19 dB. Bandwidth impedansi sebesar 52,90 MHz (2,1%) dan 43 MHz (1,76%) berturut-turut untuk simulasi dan pengukuran. Gain antena pada simulasi 10,68 dBi, sedangkan hasil pengukuran didapatkan 12,73 dBi karena fabrikasi antena dikerjakan secara manual. Simulasi SAR memperlihatkan nilai 0,03029 W/Kg (10g rata-rata jaringan tubuh) jika diberikan daya masukan 1 mW.

ABSTRACT
Currently, the use of wireless telemedicine equipment is greatly developed due to some advantages such as low power and its portability. To be used for wearable applications, telemedicine requires a suitable device that is comfortable for attaching on the human body. To do that, textile-type device is usually proposed, of which a textile antenna is required. This thesis proposes a magnetic-type textile antenna at 2.45 GHz, where the antenna design is basically inspired by traditional Cirebon batik style called mega mendung. The proposed antenna is put in the proximity of the human body model (called a phantom), in order to investigate the body effect on the antenna performances. In this thesis, two structures of magnetic antenna, namely a microstrip spiral antenna as an antenna type-1 and a microstrip spiral slot antenna as type-2, are numerically analyzed by the use of finite integration technique (FIT). According to the simulation results, both of the proposed antennas tend to have magnetic properties as the magnetic-type antenna has, which it can be seen from the electric and magnetic fields intensity within the near field region. The simulated and measured results show that the antenna type-1 resonates at 2.45 GHz in free space with |S11| is -24.15 dB and -12.09 dB, respectively. The impedance bandwidth is 27.10 MHz (1.1%) and 40 MHz (1.6%) for simulated and measured result, respectively. The antenna gain is 0.96 dBi (simulation) and 0.42 dBi (measurement) without any human body is present. When the human body model is put in proximity to the antenna and 1 mW of input power is given to the antenna, very small value of specific absorption rate (SAR) by 0.00083 W/Kg is obtained for 10g-tissue averaged standard. As for antenna type-2, the simulated and measured results show that it resonates at 2.45 GHz in free space with |S11| is -21.61 dB and -24.19 dB, respectively. The impedance bandwidth is 52.90 MHz (2.1%) and 43 MHz (1.76%) for simulated and measured result, respectively. The antenna gain is 10.68 dBi for simulation and 12.73 dBi for measurement since the fabricated antenna is manually manufactured. The simulated SAR value by 0.03029 W/Kg (10g-tissue averaged standard) is obtained when the input power of 1 mW is given"
2014
T39053
UI - Tesis Membership  Universitas Indonesia Library
cover
Abdurrahman Wahid
"Aplikasi telemedis berbasis Wireless Body Area Network (WBAN) menjadi salah satu objek penelitian yang mulai banyak dikembangkan di bidang telekomunikasi. Selain karena manfaatnya yang besar dalam meningkatkan kualitas pelayanan kesehatan, peralatan telemedis juga memiliki kelebihan dalam konsumsi daya yang rendah, mobilitas, dan kemudahan dalam melakukan pengawasan kesehatan pasien. Salah satu aplikasi untuk mendukung aplikasi tersebut adalah melalui perangkat yang dapat dipakai (wearable application) menggunakan antena tekstil. Beberapa literatur telah banyak mengembangkan antena untuk wearable application namun kebanyakan merupakan perangkat yang bersifat elektrik atau antena magnetik untuk satu frekuensi kerja. Kelemahan antena elektrik adalah ada atau tidaknya tubuh manusia di dekat antena tersebut sangat mempengaruhi kinerja antena.
Oleh karena itu, pada tesis ini dibuat antena tekstil yang bersifat magnetik dan memiliki frekuensi ganda (dualband) yang diletakkan pada model tubuh manusia yang berupa phantom numerik untuk mengetahui pengaruh tubuh manusia terhadap kinerja antena. Simulasi antena menggunakan phantom numerik yang terdiri dari 3 lapisan tubuh yaitu kulit, lemak, dan otot dengan ketebalan masing-masing berturut-turut 2 mm, 4 mm, dan 54 mm.. Ukuran phantom numerik tersebut memiliki panjang 400 mm dan lebar 400 mm. Nilai konstanta dielektrik (ɛr) phantom numerik pada frekuensi 2,45 GHz adalah 5,28 untuk lemak, 52,73 untuk otot, dan 42,85 untuk kulit. Pada frekuensi 924 MHz adalah 5,46 untuk lemak, 41,28 untuk kulit, dan 56,82 untuk otot. Sementara itu konduktivitas (σ) phantom pada frekuensi 2,45 GHz sebesar 0,104517 S/m pada lemak, 1,738776 S/m pada otot, dan 1,591923 S/m pada kulit. Untuk frekuensi 924 MHz sebesar 1,00443 S/m pada otot, 0,051615 S/m pada lemak, dan 0,874705 untuk kulit.
Hasil simulasi antena menunjukkan bahwa antena bersifat magnetik dan mampu bekerja pada dua frekuensi yaitu 924 MHz dan 2,45 GHz. Hasil simulasi antena tanpa phantom menunjukkan nilai S11 pada frekuensi 924 MHz sebesar -27,307 dB dan pada frekuensi 2,45 GHz sebesar -14,797 dB. Bandwidth yang diperoleh untuk S11 ≤ -10 dB pada frekuensi 924 MHz sebesar 11 MHz dan pada frekuensi 2,45 GHz sebesar 20 MHz. Gain antena yang diperoleh pada kondisi udara bebas sebesar -22,4 dBi untuk frekuensi 924 MHz dan -6,911 dBi untuk frekuensi 2,45 GHz. Sementara itu, ketika antena diletakkan dekat dengan phantom, hasil simulasi menunjukkan bahwa pada jarak 0 mm (menempel tubuh), nilai gain antena untuk frekuensi 924 MHz menjadi -22,71 dBi dan pada frekuensi 2,45 GHz menjadi -10,72 dBi. Nilai SAR yang diperoleh ketika antena diletakkan di dekat tubuh masih memenuhi standar yang ditetapkan oleh ICNRIP yaitu di bawah 2 W/kg.
Hasil pengukuran antena pada kondisi udara bebas menunjukkan nilai S11 pada frekuensi 924 MHz sebesar -21,45 dBi dan pada frekuensi 2,45 sebesar -19,47 dBi. Antena diukur di dekat tubuh manusia dan phantom dengan karaktersitik untuk frekuensi 924 MHz dan 2,45 GHz. Hasil pengukuran antena di dekat tubuh dan phantom masih memenuhi standar S11 yaitu di bawah -10 dBi. Hal ini menunjukkan bahwa ada tidaknya tubuh manusia tidak mempengaruhi kinerja antena.

Wireless Body Are Network (WBAN) telemedicine application is becoming one research object that developing in telecommunication sector. It is not only because the benefits in upgrading health service qualities, but also the advantages in low power consumptions, mobility and practical patient control. One of the application that support WBAN system is practicing wearable application using textile antenna. Some literatures have developed wearable application system yet. Most of them are implementing electricity tools and working only for single frequency. The disadvantages of electric antenna is the performance of the antena depend on the presence of human body near the component.
Based on that statement, in this thesis designed magnetic textile antenna that have double frequency system ( dual band) will be placed on phantom numeric human body model to discover the impact of human body on the antenna?s performance. The pantom numeric antenna simulation consist from 3 body?s layers : skin , fat , muscle with the thickness for each 2 mm, 4 mm and 54 mm. Phantom numeric numbers are 400 mm long and 400 width. Dielectric constant value of phantom numeric on 2.45 GHz frequency is 5.28 for the fat, 52.73 for muscle, and 42.85 for skin. On 924 MHz number are 5.46 for the fat,41.28 for skin and 56.82 for muscle. While phantom conductivity on 2.45 GHz frequency are 0.104517 S/m for fat, 1.738775 S/m for muscle, 1.591923 S/m for skin. On 924 MHz frequency area 1.004436 S/m for muscle, 0.051615 S/m for fat, and 0.08747 S/m for skin.
The antena simulation result shows that the antena is magnetic and works on 2 frequencies those are 924 MHz and 2.45 GHz. The simulation result without phantom shows S11 value on 924 MHz frequency is -27,307 dB and -14,797 dB on 2.45 GHz frequency. Bandwidth that resulted for S11 ≤-10 dB on frequency 924 MHz is 11 MHz and on frequency 2.45 GHz is 21 MHz. Antenna gain resulted on free space condition is -22.4 dBi for frequency 924 MHz and -6.91 dBi for frequency 2.45 GHz. While antenna placed near the phantom , it shows that on 0 mm of space (attached on the body) antenna gain value for frequency 924 MHz is -22.71 dBi and on frequency 2.45 GHz is -10.72 dBi. SAR value that resulted when antenna placed near the body is still occupy the standard that stated by ICNRIP that is below 2 W/kg.
Measurement result on free space condition shows that |S11| value on 924 MHz frequency is -21,45 dBi and on frequency 2,45 GHz is -19,47 dBi. Antena has been measured near human body and phantom for frequency 924 MHz and 2,45 GHz. The results are still occupy the standard of S11, that is below -10 dBi. That means performance of the antenna is not influenced by the presence of human body or phantom near the component."
Depok: Fakultas Teknik Universitas Indonesia, 2014
T41857
UI - Tesis Membership  Universitas Indonesia Library
cover
Adhitya Satria Pratama
"Untuk melakukan diagnosa dan evaluasi penanganan kasus medis, paramedis perlu melakukan pemindaian tubuh manusia. Beberapa teknologi pemindaian tubuh manusia yang telah ada di antaranya adalah CT-Scan dan MRI. Walaupun resolusi dan akurasi citra yang dihasilkan sangat baik, namun biayanya yang relatif mahal bagi masyarakat Indonesia dan kompleksitas peralatan CT-Scan dan MRI cukup menjadi isu yang penting. Salah satu alternatif teknik pemindaian tubuh manusia yang non-intrusif, non-invasif, dan relatif lebih murah adalah teknologi pencitraan kepala menggunakan gelombang mikro (microwave imaging).
Teknik pencitraan gelombang mikro memanfaatkan sifat gelombang mikro yang dapat menembus atau terhambur jika dihadapkan pada suatu objek dan karakteristik dielektrik sel tumor yang jauh berbeda dibandingkan sel yang sehat. Pada tesis ini dirancang bangun suatu perangkat pencitraan gelombang mikro yang terdiri dari perangkat keras berupa sistem antena, mikrokontroler, dan motor stepper serta perangkat lunak berupa pemrograman algoritma rekonstruksi citra proyeksi balik. Sistem antena ini berfungsi sebagai pengirim dan penerima gelombang elektromagnetik untuk mendapatkan parameter S21. Sistem antena, yang terdiri dari antena beserta network analyzer, terintegrasi dengan motor stepper dan mikrokontroler dalam pemrograman berbasis LabVIEW. Objek pengujian yang berupa model phantom yang terdiri dari dua lapisan dan daging sapi diletakkan di antara antena pengirim dan penerima pada frekuensi 3 GHz. Hasil pengujian berupa magnitudo koefisien atenuasi dari parameter S21 yang direkonstruksi untuk memperoleh citra objek menggunakan perangkat lunak MATLAB ®.
Kedua antena yang digunakan diukur untuk mendapatkan kinerja pada frekuensi 3 GHz meliputi parameter S11 dan pola radiasi. Pola radiasi antena dipol adalah omnidireksional, sedangkan antena tapered slot memiliki pola radiasi direktif. Berdasarkan hasil pengujian, sistem antena telah terintegrasi dengan perangkat lunak berbasis LabVIEW dan telah mampu mengambil data secara otomatis. Hasil pencitraan yang diperoleh menunjukkan bahwa antena dengan pola radiasi yang direktif relatif lebih terlihat jelas dibandingkan antena omnidireksional. Fluktuasi magnitudo koefisien atenuasi terjadi di setiap titik tertentu pada objek karena adanya perbedaan permitivitas relatif objek. Sistem pencitraan gelombang mikro telah berhasil diuji validitasnya meskipun hasil citramasih terdapat derau dan artifact yang timbul akibat interpolasi pada algoritma proyeksi balik.

MRI, PET, and CT are widely used modalities for human body scanning, which they can provide accurate and high resolution image. However, their costs are still relatively high particularly in developing countries with high population like Indonesia. Hence, it is desirable to develop a new imaging system that is affordable, easy to operate (portable), non-ionization (safe radiation) and use a non-invasive technique. Microwave imaging is considered as a suitably matched modality to those requirements.
The imaging system using microwave utilizes the microwave properties that can penetrate and be scattered when it is exposed to an object and the tumor cell?s dielectric characteristics, which usually has much different dielectric constant compared with the healthy cell. The microwave imaging system that is proposed in this thesis, consists of a set of hardware (an antenna system, microcontroller and network analyzer) and own-developed back projection-based image reconstruction algorithm. The antenna system uses either a pair of dipole antennas or pair of tapered slot microstrip antenna as a transmitter and a receiver of microwave in order to measure the S21 parameter. The antenna system, consisting of antennas and network analyzer, is integrated with the stepper motors and microcontroller by using LabVIEW program. Either a dual layer phantom or a slice of beef meat as the object is located between the transmitter and the receiver that are operated at 3 GHz. The magnitudes of attenuation coefficients obtained from the measured S21 are then reconstructed into an image using MATLAB® program.
Both tapered-slot and dipole antennas are measured to evaluate the S11 parameters and radiation pattern at frequency of 3 GHz. The dipole antenna has an omnidirectional radiation pattern while the tapered slot has a directive radiation pattern. The antenna systems has been evaluated and successfully integrated with LabVIEW program to automatically obtain the data. The reconstructed images show that the tapered-slot antenna provides clearer image rather than the dipole due to its directive pattern characteristics. Moreover, the magnitude of attenuation coefficients from both antennas are discussed, where the fluctuation occurs due to the relative permittivity differences of the object. The proposed microwave imaging system has been successfully evaluated for the validity on performing image reconstruction, although some of the reconstructed images still contain noise and artifacts due to interpolation algorithm process.
"
2015
T42926
UI - Tesis Membership  Universitas Indonesia Library
cover
Septian Wahyu Kusuma Wardhani
"Saat ini, berbagai macam peralatan nirkabel diletakkan di dekat tubuh manusia, baik secara implan maupun disematkan di permukaan tubuh manusia yang biasa dikenal dengan Body Wireless Communication System (BWCS). Selain itu, Microwave Tomography (MWT) yang sedang berkembang saat ini juga memerlukan antena yang dekat dengan tubuh manusia. Oleh karena itu, analisis studi interaksi antara perangkat wearable/implan dan tubuh manusia serta pengaruh gelombang elektromagnetik (EM) terhadap tubuh, perlu dilakukan telaah. Pada dasarnya interaksi gelombang EM dengan tubuh terdiri dari 2 tipe yaitu: pengaruh tubuh manusia terhadap kinerja antena dan pengaruh gelombang EM terhadap tubuh manusia. Agar dapat mengevaluasi studi interaksi tersebut, maka diperlukan model phantom sebagai media evaluasi.
Pada tesis ini dirancang model phantom kepala manusia, terdiri dari dua model, yaitu model phantom homogen dan phantom 2-lapis. Model phantom homogen dimodelkan sebagai jaringan otot dengan permitivitas 2/3 nilai permitivitas dan konduktivitas otot pada rentang frekuensi ultrawideband yang diinvestigasi (yaitu di 3,1 GHz, 5,8 GHz dan 7,5 GHz). Model phantom 2-lapis dimodelkan dengan jaringan kulit dan otak. Model phantom tersebut diletakkan di dekat antena dipol, loop dan mikrostrip UWB, yang disimulasikan dengan menggunakan perangkat lunak CST Microwave Studio. Ketiga tipe antena tersebut digunakan untuk menganalisis pengaruh model phantom terhadap kinerja antena tersebut.
Hasil simulasi antena ketika berada di dekat model phantom menunjukkan menunjukkan pergeseran frekuensi resonan ke frekuensi yang lebih rendah untuk antena dipol, loop dan mikrostrip UWB yang digunakan, dibandingkan ketika bekerja di udara bebas. Hal ini menunjukkan bahwa material jaringan phantom menyerap gelombang EM yang ditransmisikan antena dan mempengaruhi impedansi antena sehingga frekuensi resonansi antena bergeser. Untuk memudahkan dalam validasi melalui pengukuran maka difabrikasi model phantom fisik 2/3 jaringan otot.
Berdasarkan hasil pengukuran antena ketika didekatkan ke model phantom fisik, frekuensi resonan antena dipol, loop dan mikrostrip UWB cenderung bergeser ke frekuensi yang lebih rendah. Nilai SAR phantom yang didekatkan dengan antena dipol, loop dan mikrostrip UWB bervariasi nilainya. Pengukuran SAR dilakukan dengan metode termografi, dimana phantom dipapar dengan gelombang elektromagnet selama 30 menit dengan daya sekitar 1 Watt. Nilai SAR hasil pengukuran yang memenuhi standar IEC adalah ketika phantom berada di dekat antena mikrostrip UWB yaitu < 10 Watt/kg.

Many devices in common use today are worn either implanted, on or in the proximity to the body which is now commonly known as Body Wireless Communication System (BWCS). In addition, currently, microwave tomography (MWT) system is widely studied, which requires an antenna in close to the human body. Hence, a study on interaction between the human body and electromagnetic (EM) wave inevitably must be evaluated for wearable/implantable antennas and the effect of EM wave to the human body as well. Basically, the interaction of EM wave includes two types: an influence of the human body on the performance of antennas and an influence of EM wave on the human body.
This thesis proposes head phantom models i.e. a homogeneous phantom model and two-layers model. The homogeneous phantom is modelled as 2/3 muscle tissue in terms of its permittivity and conductivity in ultrawideband range (i.e. 3.1 GHz, 5.8 GHz and 7.5 GHz). The two-layer phantom is represented by brain and skin tissues. The phantom models are placed near to dipole, loop and microstrip UWB antennas, which are then simulated using CST Microwave Studio. Those three antennas are used to analyze the effect of phantom models on the performance of the antenna.
The simulation results when the antenna is near to the phantom models show that the resonant frequency shifts to a lower frequency for dipole, loop and microstrip UWB, comparing when they operate in free space. This shows that the phantom material absorbs the transmitted EM wave and affects the antenna impedance, so thus the resonant frequency of the antenna is shifted. In order to simplify validation by a measurement of the physical phantom model, such a phantom is fabricated by representing 2/3 muscle tissue.
According to the measured results, the resonant frequency of dipole, loop and microstrip UWB tend to shift to the lower frequency when the antenna is in the proximity to the physical phantom. The specific absorption rate (SAR) values on the phantom vary in value when the phantom is exposed to EM energy from the dipole, loop or microstrip UWB antenna. The SAR measurement is conducted by using thermographic method, where the phantom is exposed to EM wave for 30 minutes by an input power of about 1 Watt. The measured SAR values agree with the IEC standards (i.e. less than 10 Watts/kg ) when the phantom is exposed to EM wave by using an UWB microstrip antenna.
"
Depok: Fakultas Teknik Universitas Indonesia, 2015
T43753
UI - Tesis Membership  Universitas Indonesia Library
cover
Yasintus Toin Runesi
"Tesis ini merupakan penelisikan teoritis mengenai pluralitas masyarakat semasa ini, dalam kerangka pemikiran teori kritis Axel Honneth. Berangkat dari faktisitas sosio-politik, yang ditandai dengan intensitas keragaman nilai, ideologi, gaya hidup, terjadi pula penajaman perbedaan identitas entah itu bersifat etno-kultural maupun etno-religius. Akibatnya, di satu sisi, kita menemukan dalam masyarakat adanya gejala eksklusivitas mayoritas terhadap minoritas, atau antaretnis dan antaragama akibat gesekan-gesekan sosial, dan di sisi lain, ada upaya untuk mengatasi problem semacam itu dengan mendorong inklusivitas sosial dalam masyarakat. Dengan menggunakan teori pengakuan Axel Honneth, yang dipahaminya sebagai sarana realisasi-diri individu, tesis ini menyatakan bahwa melalui pengakuan intersubjektif, terbuka kemungkinan masyarakat semasa menemukan jalan dialog bagi kebertemuan yang secara legal-normatif menjamin hidup bersama secara berdamai dan berkeadilan. Sehubung itu, dalam tesis ini, pengakuan intersubjektif disebut sebagai prinsip pro-eksistensi masyarakat plural.

This thesis is a theoretical scrutinize of the plurality of contemporary society, in the framework of critical theory of Axel Honneth. Departing from socio-political facticity, which is characterized by the intensity of the diversity of values, ideology, lifestyles, there is also sharpening difference whether it is the identity of ethno-cultural as well as ethno-religious. What emerges is, on the one hand, we find in society the symptoms of exclusivity between different societies, majority against minority, or interethnic and interreligious due to social friction, and on the other, there is an attempt to overcome such problems by encouraging social inclusiveness in agonistic society. By using the theory of Axel Honneth of intersubjective recognition, which is understood as a means of individual selfrealization, this theses states that through intersubjective recognition, opens the condition of finding the path of dialogue during the society for meeting between different socially community, which legally guarantees coexist peacefully and equitably. In this way, I call intersubjective recognition as the principle of proexistence in a plural society."
Depok: Universitas Indonesia, 2015
T43830
UI - Tesis Membership  Universitas Indonesia Library
cover
Nayla Najati
"Negara Kesatuan Republik Indonesia membutuhkan satelit mikro untuk pengawasan wilayah nusantara. Satelit mikro yang memiliki berat 10-100 kg telah menjadi titik awal pengembangan teknologi satelit di Indonesia dengan diluncurkannya satelit mikro generasi pertama, LAPAN-A1 (lebih dikenal sebagai LAPAN-TUBSAT) pada 10 Januari 2007.
Dalam operasinya, satelit mikro LAPAN-A1 membutuhkan antena untuk sistem komunikasi antara satelit dan stasiun bumi. Sistem komunikasi ini berupa pengiriman data satelit/citra satelit dan data telemetry & telecommand. Pada sistem komunikasi telecommand digunakan antena yang bekerja pada pita frekuensi UHF (frekuensi tengah 437,325 MHz) dengan tipe antena wire monopole. Antena monopole tersebut memiliki panjang 1/4λ (sekitar 17 cm), sehingga memerlukan tempat yang relatif luas dalam proses peluncuran. Dalam rangka pengembangan antena UHF berikutnya diharapkan antena yang lebih kompak dapat digunakan pada satelit mikro generasi berikutnya.
Pada tesis ini diusulkan sebuah antena yang dirancang untuk aplikasi telemetry&telecommand satelit mikro pada frekuensi 430 ? 450 MHz yang memiliki dimensi yang lebih kecil dan kompak. Jenis antena yang dipilih adalah antena mikrostrip tipe meander, memiliki polarisasi linier, dan pola radiasi omnidirectional.
Hasil simulasi menunjukkan antena satu elemen yang dirancang memiliki frekuensi kerja pada 461 ? 481 MHz, dengan gain 2,69 dBi, berpolarisasi linier, dan memiliki pola radiasi mendekati omnidirectional pada bidang azimuth. Sedangkan hasil simulasi pada badan satelit, antena yang dirancang memiliki frekuensi kerja pada 428 ? 468 MHz, dengan gain 2,9 dBi. Hasil pengukuran antena satu elemen menunjukkan frekuensi operasi berada pada kisaran 457 - 492 MHz, dengan pola radiasi mendekati omnidirectional pada bidang azimuth. Untuk hasil pengukuran antena terpasang pada badan satelit, memiliki frekuensi kerja pada 403 - 450 MHz dengan besar bandwidth mengalami kenaikan ±30% bila dibandingkan dengan antena satu elemen.

Republic of Indonesia require microsatellite for monitoring the archipelago. Microsatellite that weight about 10-100 kg which was launched on 10, January 2007, was the starting point for the development of satellite technology in Indonesia. The microsatellite LAPAN-A1 requires an antenna for communication systems between satellite and ground stations.This microsatellite can send satellite imagery (payload data) and telemetry & telecommand.
The telecommand system used monopole antenna that works at UHF band with center frequency at 437,325 MHz. This wire monopole antenna has a length of 17 cm, so it requires a relatively large space in the process of launching. In order to develop the next UHF antenna, more compact UHF antenna design is expected and can be used in the next generation of microsatellites.
This thesis proposed an antenna design for telemetry and telecommand applications of microsatellite in the band frequency 430-450 MHz which has smaller dimensions and compact. The type of antenna selected is meander microstrip antenna. This antenna has a linear polarization and omnidirectional radiation pattern. Simulation results shows that antenna design has working frequency at 461 ? 481 MHz with gain of 2.69 dB, linier polarized, and has nearly omnidirectional radiation pattern.
The simulation results, when antenna mounted on the body of the satellite, has working frequency at 428-468 MHz with a gain of 2.9 dBi. The measurement results of the single element antenna shows that the operating frequency is in the range of 457-492 MHz with nearly omnidirectional radiation pattern in azimuth plane. For the measurement antenna mounted on the satellite body, it has working frequency 403-450 MHz with increase of bandwidth ± 30 % when compared to a single element antenna.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
T50155
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9   >>